Cybersecurity

UniFi Access Bulletin 073: Seven Flaws in the App That Runs Your Doors, and How I'd Patch

Illustration of a black wall-mounted door reader with a small screen beside a light switch, with a speech bubble showing a crossed wrench and screwdriver, next to a hallway with a closed wooden door

On Wednesday, November 18, Ubiquiti published Security Advisory Bulletin 073 for the UniFi Access application. It covers seven vulnerabilities, five of them rated critical, and the fix for all of them is UniFi Access 4.3.24 or later.

I’ve written about UniFi bulletins before (069 for gateways, 070 for the AI Key and camera appliances). This one gets a different kind of attention from me, because UniFi Access is what decides who gets through a door or a gate. We design and install UniFi Access systems for offices and driveway gates, so this is the one I’d want patched before the weekend.

What’s in Bulletin 073

Ubiquiti’s bulletin lists UniFi Access 4.3.22 and earlier as affected. Some CVE records describe the range as “before 4.3.24,” which comes to the same thing in practice: if you’re not on 4.3.24 or later, update. The CVEs were published Thursday.

CVE Type CVSS What it can lead to
CVE-2026-132802 Improper link resolution 9.9 Arbitrary code execution as root on the host device
CVE-2026-132803 Authenticated SQL injection 9.9 Privilege escalation on the host
CVE-2026-132804 Server-side request forgery 9.9 Changing host settings
CVE-2026-132808 Incorrect authorization 9.9 Running commands on certain adopted Access devices via the host
CVE-2026-132807 Improper certificate validation 9.0 Critical, under specific conditions
CVE-2026-132806 Authenticated SQL injection 8.8 Reading data or gaining admin rights
CVE-2026-132805 Server-side request forgery 8.3 Requires network access only, no account

The worst of them, in Ubiquiti’s words: “A malicious actor with access to the network and low privileges could exploit an Improper Link Resolution Before File Access vulnerability found in UniFi Access Application to execute arbitrary code with root privileges on the host device.”

As of the reports I’ve read, none of the seven are known to be exploited, and none are in CISA’s Known Exploited Vulnerabilities catalog. That’s good news, and it’s also the window to patch in.

The phrase that matters: “network access and low privileges”

Most of these bugs need two things: the attacker can reach the console over the network, and they have some account, even a limited one. One of the SSRF bugs needs only network access.

That’s worth thinking about for access control specifically, because of who tends to have accounts and who tends to be on the network:

  • Low-privilege accounts are common in Access deployments. Office managers who add and remove credentials, front-desk staff who look at entry logs, a property manager who opens the gate remotely. Those are exactly the “low privileges” these bugs start from.
  • The console is often on a flat network. In small offices especially, the console that hosts UniFi Access sits on the same network as staff laptops, and sometimes the guest Wi-Fi isn’t as separate as people think.
  • Root on the host is a big prize. The device that runs Access may also be running other UniFi applications. Root on it isn’t just a door problem.

So “it needs an account” is not much comfort. The question is who can reach the console and what accounts exist on it.

How I’d work the patch

Flowchart: find every site running UniFi Access, check the Access application version on each console; if it’s 4.3.24 or later, record the version and date; if not, back up the console, update the Access application, then test a credential at each door, a request-to-exit button, the gate and the logs before recording it. Finally, review who can reach the console: admin accounts, VLANs and remote access. The order I’d work through it. The last step is the one that keeps the next bulletin from being urgent.

  1. Find every site running UniFi Access. Check UniFi Site Manager for every console you manage, including the small ones running a single gate.
  2. Check the Access application version on each console. Anything below 4.3.24 needs the update.
  3. Back up the console first. Make sure a current backup exists before you touch anything that controls doors.
  4. Update the UniFi Access application. This is an application update on the console, not firmware on each reader.
  5. Test the doors, not just the dashboard. Badge in at each door with a real credential, press a request-to-exit button, open the gate, and confirm each event shows up in the access log. A door that won’t unlock on Friday evening is a bigger problem than a pending update.
  6. Record the version and date. Whatever you use to track client sites, write it down. When the next bulletin lands, you’ll know in minutes which sites need attention.

📝 Note: Schedule the update for a time when someone is on site or can get there. If a door lock or gate misbehaves after an update, you want a person nearby, not a call from someone locked out.

Then look at who can reach the console

Patching closes these seven bugs. Limiting who can reach the console reduces the damage from the next ones.

A quick test I like: from a device on the guest Wi-Fi, the camera VLAN, or any network that shouldn’t manage anything, see whether the console answers. It needs only Bash and the timeout command from coreutils, which every mainstream Linux distribution already includes, so it runs on a Linux laptop or a Raspberry Pi without installing anything:

#!/usr/bin/env bash
# reach-check.sh: run from a device on a network that should NOT reach the console.
# Usage: ./reach-check.sh 192.168.1.1
CONSOLE=${1:?usage: reach-check.sh <console-ip>}

command -v timeout >/dev/null 2>&1 || { echo "This script needs 'timeout' (GNU coreutils)." >&2; exit 1; }

for port in 22 80 443; do
  if timeout 3 bash -c "exec 3<>/dev/tcp/$CONSOLE/$port" 2>/dev/null; then
    echo "$CONSOLE:$port  OPEN from this network, review your firewall rules"
  else
    echo "$CONSOLE:$port  closed or filtered"
  fi
done

If anything comes back open from a guest or IoT network, that’s a firewall rule to add in UniFi Network: block that network from reaching the console’s management address, and allow only the networks and admin devices that need it.

While you’re in there:

  • Review the accounts. Remove anyone who’s left, and make sure people who only need to manage credentials or view logs don’t have more access than that.
  • Turn on multi-factor authentication for every UniFi account that can sign in remotely.
  • Check remote access. If a client doesn’t use remote management, there’s no reason to leave it on.

Why access control deserves the fast lane

Most of the time I’m happy to let a UniFi update sit for a few days while other people find the rough edges. Access control is different. A camera system with a vulnerability can be watched and fixed; a door system with one is the thing standing between someone and the building. Five critical flaws, a root code execution bug, and no known exploitation yet is exactly the situation where I’d rather patch now than read about it later.

If you have UniFi Access on your doors or gate and aren’t sure what version you’re on, or who can reach the console, get in touch. It’s a quick check.

Sources

Your next project starts here

Let’s build something that works.

A new building, a camera system for the back forty, or a network that needs a fresh start. Tell us what you’re working with — the first conversation is free.

Or email hello@emeraldsecurity.net